SINTERFACE

Bubble Pressure Tensiometer

BPA-2S

Dynamic surface tension without limits.

The BPA-2S is our flagship maximum bubble pressure tensiometer, delivering precise dynamic surface tension measurements from less than one millisecond up to 100 seconds. Designed for advanced research, it combines exceptional time resolution, stand-alone operation and scientific accuracy within a single instrument.

SINTERFACE BPA-2S Maximum Bubble Pressure Tensiometer

<1 ms

Surface age

100 s

Dynamic range

6 Orders

Time interval

The BPA-2S platform

The widest dynamic time window in bubble pressure tensiometry.

The BPA-2S is the flagship instrument of the BPA series, providing precise dynamic surface tension measurements over six orders of magnitude in time. Based on the Fainerman measurement protocol, it accurately separates bubble dead time from bubble lifetime to characterize extremely fast adsorption processes.

From sub-millisecond interface formation to long-term adsorption studies, the BPA-2S enables comprehensive investigation of surfactants, inks, coatings, pharmaceuticals and other dynamic liquid systems using a single measurement platform.

Capabilities

One platform. Endless possibilities.

Discover the measurement capabilities and integrated technologies of the PAT-1P.

Scientific dynamic surface tension measurements

Measure dynamic surface tension with exceptional precision over six orders of magnitude in surface age.

Separate bubble dead time and lifetime to obtain reliable dynamic surface tension data below one millisecond.

Investigate micelle formation, inkjet printing and coating applications at extremely short adsorption times.

Operate the instrument independently using the embedded computer, touch display and integrated data storage.

Compare multiple measurements graphically, zoom into adsorption processes and export data directly for scientific evaluation.

Specially designed capillaries enable extremely small bubble volumes and exceptionally short dead times.

Performance

Engineered for reproducible results.

The PAT-2S combines high-resolution imaging, precise mechanics and advanced analysis software to deliver reliable measurement data for demanding interface research.

0.1 ms

Minimum surface age

Capture ultra-fast adsorption processes below one millisecond using specialized capillaries.

6 Orders

Time interval

Dynamic surface tension measurements spanning six orders of magnitude.

0.005mN/m

Resolution

High-resolution pressure analysis for demanding scientific applications.

1 ml

Minimum sample volume

Reliable measurements with minimal sample consumption.

Values may depend on configuration, measurement mode and optional modules.

Measurement principle

Resolving the fastest interfacial processes.

The BPA-2S applies the Maximum Bubble Pressure Method together with the Fainerman measurement protocol to separate bubble dead time from bubble lifetime. This enables highly accurate determination of dynamic surface tension from less than one millisecond up to 100 seconds, providing unique insight into adsorption kinetics, surfactant transport and rapidly evolving liquid interfaces.

Scientific visualization of Maximum Bubble Pressure measurements with the BPA-2S

Measurement method

Maximum Bubble Pressure

Surface age

<1 ms – 100 s

Protocol

Fainerman Method

Accessories

Extend your BPA-2S.

Configure the BPA-2S with specialized accessories for ultra-fast dynamic surface tension measurements and advanced laboratory workflows.

Special capillaries for BPA-2S

Accessory

Special Capillaries

Special capillary geometries enable measurements down to 0.1 milliseconds and support extremely small bubble volumes.

Learn more

BPA-2S Configurator

Configure your BPA-2S.

Configure the BPA-2S for ultra-fast dynamic surface tension analysis by selecting capillary systems, software features, connectivity options and laboratory accessories.

Special capillaries
Advanced measurement modes
Stand-alone & remote operation
Configurable SINTERFACE BPA-2S Maximum Bubble Pressure Tensiometer
Special Capillaries

Special Capillaries

Ultra-fast measurements

SSD Storage

SSD Storage

64 GB onboard

Modular system

Select modules, options and accessories individually.

Applications

Engineered for the fastest interfacial processes.

The BPA-2S supports cutting-edge research and industrial process development wherever dynamic surface tension at extremely short adsorption times determines product performance.

Dynamic surface tension analysis for industrial inkjet printing

Industrial inkjet printing

Investigate droplet formation at extremely short adsorption times for high-speed printing applications.

Wastewater monitoring using the BPA-2S

Wastewater monitoring

Detect trace surfactant concentrations through highly sensitive dynamic surface tension measurements.

Industrial cleaning bath monitoring

Industrial cleaning

Monitor dynamic wetting behavior and surfactant performance in industrial cleaning processes.

Mineral flotation research

Mineral flotation

Optimize flotation efficiency through dynamic bubble-interface characterization.

Electroplating bath analysis

Electroplating baths

Control plating bath quality by monitoring dynamic surface tension and wetting behavior.

Pulmonary surfactant research

Lung surfactant research

Study adsorption kinetics of pulmonary surfactants for respiratory and biomedical research.

Scientific publications

Thousands

Publications and scientific references related to interface characterization.

Trusted for advanced dynamic interface research.

Explore peer-reviewed publications covering maximum bubble pressure tensiometry, ultra-fast adsorption kinetics, surfactant dynamics and high-speed interfacial phenomena.

Verified SINTERFACE instrument use will be clearly distinguished from recommended scientific literature.

Technical information

Scientific performance. Comprehensive specifications.

Explore the complete measurement capabilities, hardware architecture and software features of the BPA-2S Maximum Bubble Pressure Tensiometer.

Dynamic surface tension

Interfacial tension

Maximum bubble pressure method

Bubble dead time determination

Bubble lifetime analysis

Surface tension as a function of physical and adsorption time

Hydrostatic pressure determination

Hydrodynamic correction

Gravitational correction

Viscosity correction

Liquid viscosity estimation

Temperature monitoring and control

Surface and interfacial tension

Measurement range
10–150 mN/m
Resolution
0.005 mN/m
Surface tension accuracy
Better than 0.5 %
Density accuracy
2 %

Dynamic measurements

Standard capillary
10 ms – 200 s
Special capillary
0.1 ms – 100 s
Minimum sample volume
1 ml
Measurement temperature
0–100 °C

Standard mode

Constant time mode

Fast scan mode

Increasing flow mode

Short lifetime mode

Density estimation

Viscosity estimation

Custom measurement mode

Up to 180 measurement points in scan modes

Unlimited measurements in constant mode

Standard mode (M1)
20–30 min
Fast mode (M4)
4–6 min
Operation
Stand-alone or remote control
Display
7'' TFT color touch display
Resolution
800 × 480 px
Storage
64 GB SSD, USB memory, Network storage
Ethernet
1 GB
USB
2 × USB 2.0, 1 × USB 3.0
WiFi
Optional
DisplayPort
Up to 1920 × 1200

Windows Embedded Standard WES7

Stand-alone operation

Remote operation

Automatic liquid-level determination

Automatic capillary immersion

Graphical comparison of multiple measurements

Interactive zoom functions

Export to text files

Direct Microsoft Excel export

Automatic and manual critical flow determination

Fainerman measurement routine for ultra-short adsorption times

Built-in storage for up to 180 measurements

Free software updates for one year

Dimensions
300 × 400 × 350 mm
Weight
5 kg
Operating environment
10–50 °C
Power supply
24 VDC
Power adapter
100–240 VAC
Maximum power consumption
<15 W

Standard capillaries

Special capillaries

Capillaries of different diameters

Temperature control accessories

Specifications may vary depending on configuration, software version and optional modules.

Downloads

Documentation at a glance.

Access product information, software documentation and technical resources for the BPA-2S.

Additional manuals and software downloads are available through the SINTERFACE customer portal.

Visit download center

BPA-2S

Ready for ultra-fast interface analysis?

Discuss your research or industrial application with our specialists and configure the optimal BPA-2S system for advanced dynamic surface tension measurements.

Application consultationConfiguration supportGlobal technical assistance